SCO OpenServer 6 Integration Specification

form date: 3-17-2005

If you have ordered a SCO OpenServer 6 system to be integrated by DTR, please fill in the following blanks and then click the Submit button found at the buttom of this page.

Enter your name (REQUIRED)
Enter your company name (REQUIRED)
Enter your email address (optional)
Type an identifying phrase so we will know which system or site this info applies to (eg end-user company name, address, and/or server function)

Enter the desired system name (max 8 characters, no punctuation)
Enter the desired DNS domain name

Security Profile
High (Above C2)
Improved (C2)
Traditional (default)
Low

Time Zone
Eastern
Central
Mountain
Pacific
Other (specify in special instructions at the end)

Day Light Saving Time Observed ?
Yes
No

If disks are in a RAID array, setup this RAID level:

Disk Drive 0 (where the Operating System will be installed)

drive 1 (if present) drive 2 (if present) drive 3 (if present) drive 4 (if present)

first NIC card (ethernet) or leave the default DTR test values: 10.1.1.200 255.0.0.0
IP address
Network mask
Default gateway or leave blank to set this later
DNS server or leave blank to set this later

second NIC card (if any) or leave the default DTR test values: 192.168.20.100 255.255.255.0
IP address (cannot be in same subnet as first NIC) or enter BACKUP if you want the 2nd NIC to take automatically take-over for the first NIC if it dies.
Network mask

The Intel Advanced IMM (Intel Mgmt Module) is an extra cost option that provides an additional ethernet port that can be used, via telnet or browser, to check the hardware health, fans, power supply(s). Allows rebooting a down system. Allows remote KVM for checking/changing the bios, bios raid, watching the system boot, normal login and applications, and seeing the last error even if hung with screen saver on.
Adv IMM IP address (cannot match any other IP in this server)
Adv IMM Network mask
Adv IMM Default Gateway address
Adv IMM admin user name
Adv IMM admin password

Email subsystem
mmdf
sendmail (DTR default)

root password (should not be a dictionary word or name)

COM1 serial port, I usually prefer
modem, if ordered
UPS cable, if UPS ordered
UniBasic Passport device, if ordered

COM2 serial port, I usually prefer
modem, if ordered
UPS cable, if UPS ordered
UniBasic Passport device, if ordered

If any Digi PortServers are on the order
Install RealPort SW
IP, NetMask, Gateway for first PortServer
    (Add IP, NetMask, Gateway for other PortServers under Special Instructions below)

Enter any other special instructions or requests: (Please press ENTER at the end of each line so no line is too long. You may copy/paste into this box as it will hold thousands of characters of input.

Please review all of the above information and then click the Submit button to send it to the DTR Integration group. You do not need to do anything further after you click Submit below.